BWF COLUMN: Simulated glazing bars: Balancing tradition & performance

11 minutes ago
3 min read

BWF Technical Director Kevin Underwood explores the evolution of simulated glazing bars and how to balance traditional window aesthetics with modern thermal performance


Kevin Underwood, BWF Technical Director
Kevin Underwood, BWF Technical Director

How can modern double glazing reproduce the slender sightlines of traditional windows without compromising thermal performance? In this article, I will explore the evolution of simulated glazing bars, comparing integral and applied systems and explaining the practical detailing needed to achieve durable, attractive results in contemporary joinery.


The move to double glazing


The 1980s saw the transition from single to double glazing, with windows originally designed to accommodate 4mm single panes being modified to accept 14mm (4/6/4) air-filled double-glazed units without a low-emissivity coating. These units were typically installed using a fully bedded system in rebates that were neither drained nor vented.


These windows typically had 15mm rebate upstands and a 32mm rebate platform, allowing for 3mm of front and back bedding. This meant applying sealant either side of the 14mm unit, between

the rebate upstand and the back of the glazing bead, with 3mm of edge bedding.


BS 6262:1982, Code of practice for glazing for buildings, provided guidance on edge cover to support wind loads, edge clearance to ensure that the accumulation of tolerances didn’t prevent individual panes or units from being fitted and appropriate sealant thicknesses for different applications.


Replicating traditional sightlines


Traditional glazing bars, incorporating two glazing rebates either side of a central web, needed to be at least 36mm wide on elevation to accommodate double-glazed units. By comparison, glazing bars from the late Georgian period could be as narrow as 16mm on elevation.


An alternative to traditional glazing bars was therefore needed to replicate the slender sightlines of the late eighteenth and early nineteenth centuries.


Joinery manufacturers began applying timber mouldings to the internal and external faces of double-glazed units. This approach worked well with units featuring narrow, 6mm cavities. However, as demand for lower U-values increased, cavity widths grew. This made it possible to see the back of the tape bonding the timber moulding to the external pane from inside the building. It could also leave a visible gap between the internal and external mouldings.



Integral bars & thermal performance


One solution was to incorporate bars between the two panes of a double-glazed unit. These are variously known as integral, Georgian or internal bars. Initially, these bars were made from aluminium and coloured to match the finished window, usually white. In some cases, they were used without additional profiles applied to the internal and external faces of the unit.


More recently, internal bars have been selected to match the warm-edge, low-conductivity spacer bars used around the perimeter of double-glazed units. Internal and external profiles can then be added to the glass faces in colours matching the window. However, incorporating internal bars increases a window’s U-value. BS EN 14351-1, Windows and doors – Product standard, performance characteristics – Part 1: Windows and external pedestrian doorsets, Annex J, indicates that bars applied to the internal and/or external faces of the glass have no effect on the window’s U-value.


By contrast, one internal bar increases the U-value by 0.1W/(m²·K), while multiple internal bars increase it by 0.2W/(m²·K). Traditional glazing bars are shown to increase the window’s U-value by 0.4W/(m²·K).



Externally applied bars & bonding tapes


To reduce costs while maintaining low U-values, housebuilders have adopted the use of one or more bars applied only to the external face of the outer pane. These can be bonded using black double-sided tape or mechanically fixed at the edges of the opening as a cassette.


With the latter approach, dirt can accumulate in the space between the back of the applied profile and the glass. Sealant is therefore applied along the edges of the profiles to prevent contamination. A groove is often moulded or extruded into the bar profile to accommodate the sealant.


Black, closed-cell bonding tapes are preferred because, when used without a sealant cap, they are less likely to show any dirt that accumulates. White tapes are best avoided when the rear bonding face is visible, as they can become contaminated and unsightly. Where tapes are used, they must be applied correctly and in accordance with the tape manufacturer’s recommendations.